A pneumatic magnet gripper gives a robot a way to pick up suitable steel workpieces using magnetic attraction. In a collaborative robot application, integrating this end effector involves more than attaching it to the arm: engineers must account for workpiece thickness, acceleration, mounting, pneumatic settings and the risks associated with magnetic attraction. Careful setup helps support stable handling and safer maintenance.
How a pneumatic magnet gripper works
The gripper converts compressed-air energy into mechanical movement. Its double-acting piston moves a magnet between a workpiece-holding position and a release position. When the magnet moves toward the attraction surface, magnetic holding force is generated. When it moves away, the workpiece can be released.
The specified operating pressure is 0.2 to 0.6 MPa, with a proof pressure of 0.9 MPa. At 0.5 MPa, the stated gripping force is 160 N for a 2 mm workpiece and 200 N for a 6 mm workpiece. These are specified values for the stated conditions—not a substitute for evaluating the actual part, robot motion and application. The residual holding force is 0.3 N or less.
For vertical lifting, do not assess suitability by workpiece mass alone. Acceleration, air pressure and impact also affect the load on the gripper. The workpiece’s centre of gravity matters, too: positioning the load to minimize moments on the gripper can help avoid unnecessary mechanical stress.
Pneumatic magnet gripper installation and integration
Begin installation only after reviewing the applicable safety instructions. Provide enough space for inspection and maintenance, and position the robot arm so the gripper can be mounted comfortably. The specified mounting method uses M6x23 hexagon socket head cap screws, tightened to a maximum torque of 6.3 N·m. Use a positioning pin to align the mounting holes. Excessive tightening torque can cause malfunction, while insufficient torque may allow slippage and dropping.
Handle the unit carefully during mounting. Dropping or striking it can scratch or dent the gripper, and even slight deformation may cause malfunction. Avoid impact loads on the centre of the magnetic attraction surface. Also be alert to magnetic attraction from nearby metal parts, particularly when the piston is on the attraction side.
For electrical integration, the specified auto switch is a three-wire PNP type, and the cable uses an M8 8-pin connector. The connector should not be energized while being secured. Once attached, check that it is not loose. Confirm that wiring, valve control and robot signals are correctly connected before commissioning.
Prepare pneumatic connections carefully. Clean chips, cutting oil and dust from piping before connecting it. Keep sealant out of the ports; when using seal tape, leave one thread exposed at the end of the fitting. Tighten fittings to the specified torque. The gripper does not require lubrication in service.
Control motion and prevent workpiece sideslip
The workpiece-holding time is the time taken for the piston and magnet to travel from the release position to the holding position. Workpiece-release time describes travel in the opposite direction. These times can be adjusted by changing the opening of the metering speed controller valves.
Use a flat-blade screwdriver to adjust the valves, and keep their restrictions approximately equal. A large difference between settings can make operation unstable. During horizontal movement, acceleration or friction between the pad and workpiece can cause sideslip. If lateral movement occurs, reduce the acceleration rate to minimize or prevent it.
If several grippers are used to transfer a workpiece with a large surface area, distribute them evenly. This helps avoid concentrating the load in one area. For inclined or vertical use, apply an adequate safety factor; the stated gripping-force figures alone do not establish suitability for every orientation or motion profile.
Check the operating environment
Keep the gripper within the applicable temperature and operating specifications. The product specifications list an ambient and operating temperature range of -10 to +50°C, with no freezing; the individual gripper specification lists -10 to +60°C. Confirm the limits applicable to the complete assembly and installation before use.
Do not use the unit where corrosive gases, chemicals, salt water, steam or explosive atmospheres are present. Avoid direct sunlight unless a suitable protective cover is used. The gripper should also be kept away from excessive vibration or impact, radiant heat beyond its specifications, and locations where dust, water or oil can reach the product.
Maintenance and safe servicing
Maintenance on pneumatic systems should be performed by qualified personnel. Before work begins, switch off electrical power, isolate the pressure supply and confirm that air has been released to atmosphere. Compressed air can be hazardous if handled improperly.
After installation or maintenance, restore operating pressure and power as appropriate, then perform functional and leakage tests. If electrical connections were disturbed, reconnect them correctly and carry out required safety checks. Do not modify or disassemble the product except where installation or maintenance instructions require it. Before removing the gripper, verify that no workpiece is being held and release the compressed air.
Plan for reliable robotic handling
A pneumatic magnet gripper can be an effective collaborative robot end effector when the workpiece and operating conditions suit magnetic handling. The practical priorities are to verify force requirements under real motion conditions, mount and connect the unit correctly, balance metering-valve settings, and control acceleration to limit sideslip. Applying the specified environmental and maintenance precautions supports safer integration and more predictable workpiece handling.