You are viewing the technical directory listing for Collaborative Robot Air Gripper: Setup and Safety Guide. This engineering resource is curated under our Collaborative Robots division to support automation specialists, control systems engineers, and manufacturing technicians looking for verified reference materials.

🔍 Contextual Abstract & Technical Scope

Share Summary:LinkedInEmail

A collaborative robot air gripper can provide a compact pneumatic method for handling workpieces, but reliable integration depends on more than selecting a gripper that fits the robot. Engineers and integrators need to account for gripping force, finger travel, workpiece geometry, air quality, electrical connections and safe installation. The SMC JMHZ2-16D-X7400B-ASSISTA(-P) unit brings a double-acting air gripper, a three-port solenoid valve and auto switches into a robot-hand assembly. Its specifications and installation guidance illustrate the practical checks required when commissioning this type of end effector.

Collaborative robot air gripper specifications to check

The assembled unit has a 16 mm bore, a 10 mm opening and closing stroke, and a maximum operating frequency of 120 cycles per minute. It operates on compressed air at 0.1 to 0.7 MPa. The assembled unit’s stated ambient and fluid temperature range is -10 to 50°C, so that limit should guide system-level planning. The standalone JMHZ2-16D gripper has a separately stated temperature range of -10 to 60°C; the two sets of specifications should not be treated as interchangeable.

Repeatability is specified as ±0.01 mm. That figure is one consideration in an application, not a guarantee of finished-cell positioning accuracy: the selected attachment, workpiece shape, mounting and robot motion all matter to the gripping task. The unit uses an ISO 9409-1-31.5-4-M5 mounting interface and an M12 eight-pin connector. Confirm robot-side mechanical and electrical compatibility before installation.

Match gripping force and finger geometry to the workpiece

The documented gripping-force values are 32.7 N for external gripping and 43.5 N for internal gripping, expressed as actual force per finger. These values apply when all fingers and attachments are in contact with the workpiece. They are not a substitute for checking the application’s contact conditions or the manufacturer’s gripping-force and gripping-point graphs.

Two dimensions are particularly important during tooling design:

  • Gripping point (L): where the fingers contact the workpiece.
  • Overhang (H): the distance associated with the workpiece extending beyond the supported gripping region.

Keep both dimensions within the limits shown for the applicable operating pressure in the product documentation. Operating outside those limits can adversely affect gripper life. Choose attachment geometry and contact surfaces with the actual workpiece in mind, and secure attachments using the specified fasteners and tightening torque. For the JMHZ2-16D finger attachment, the listed M3 × 0.5 bolt maximum tightening torque is 0.59 Nm.

Plan mounting, connections and speed adjustment

Before mounting, make sure there is enough room for installation, inspection and maintenance. Use the supplied positioning pins and mounting hardware as directed, and avoid impacts or deformation that could affect operation. During cover installation, take care not to trap the auto-switch cable. The guide also cautions against energizing the unit while securing its connector; check that the connector is secure before operation.

The M12 connector assigns separate pins to the 24 VDC supply, ground, valve commands for opening and closing, and the auto-switch signals. Pins 5 and 6 are identified as not connected. Wiring should follow the documented pin layout and be checked against the robot or controller interface before power is applied. The supplied auto switch is available in NPN or PNP output versions, so confirm the selected version is compatible with the receiving input circuitry.

Finger opening and closing speed can be adjusted at the metering valves using a flat-blade screwdriver. Keep the two restrictions approximately equal; a large difference may make operation unstable. Make adjustments incrementally and verify the resulting movement with the workpiece and the intended operating sequence.

Protect pneumatic performance with clean air

Air preparation is part of gripper integration, not an optional afterthought. The guidance calls for clean compressed air and an upstream air filter with a filtration degree of 5 ÎŒm or less. Where needed, use an aftercooler, air dryer or water separator to address moisture and other contamination. Drain filter bowls regularly; accumulated condensate can enter the lines and cause pneumatic equipment to malfunction.

Do not use air containing chemicals, synthetic oils, salt or corrosive gases. Extremely dry air may also degrade lubrication properties inside equipment. If the fluid temperature falls to 5°C or below, moisture may freeze and damage seals, so take appropriate precautions. Before connecting piping, flush or clean it to remove chips, oil and dust. The gripper is non-lubricated and factory lubricated; if lubrication is introduced, the manufacturer specifies turbine oil Class 1, no additives, ISO VG32, and says lubrication must then continue.

Build safety into commissioning and maintenance

A pneumatic gripper can release a workpiece if air pressure drops because of a supply problem or power failure. Assess the risk of a dropped load and provide suitable safeguards. Use protective covers where fingers or workpieces could create a hazard, and keep people and objects out of the gripper’s carrying path. The product is intended for compressed-air systems and must remain within its specified operating conditions.

Only appropriately trained personnel should install, operate and maintain the equipment. Before removing the gripper or servicing the system, secure any workpiece against falling, isolate electrical power and air pressure, and exhaust residual compressed air. Before restarting, take measures to prevent unexpected movement. Regularly remove moisture from air filters and inspect the installation as part of the wider cell maintenance routine.

Practical takeaway

Successful use of a collaborative robot air gripper begins with application checks: verify robot-interface compatibility, select attachment geometry within the gripping limits, confirm wiring and switch type, and provide clean, correctly prepared compressed air. Follow the specified installation and torque instructions, balance the speed-control settings, and plan for pressure-loss and maintenance hazards. These steps help engineers integrate the gripper with a clear understanding of its operating limits and the safeguards the surrounding system requires.